WebPage 5 PTFM 1.0 Portable Transit Time Flow Meter QUICK BENCH TEST In the PTFM Setup menu set parameters to perform a bench test: - Set Fluid = Water - Set … WebGreyline Stingray 2.0 Portable Area Velocity Flow Meter Part: Stingray 2.0 Portable long-life battery powered area velocity (level and flow) logger for open channels, partially filled pipes, and surcharged pipes without a flume or weir. Starting at $4,920.00 Request a Quote Need Help? Ask an Expert! 888-722-5543 Chat with Us Product Details

Greyline Instruments - Pulsar Measurement

WebPlease read this manual carefully before installation and operation. Any unauthorized repairs or modifications may result in a suspension of the warranty. Available in Adobe Acrobat pdf format Page 4 SLT 5.0 Level and Flow Monitor CONNECTIONS: POWER INPUT: The standard model requires AC power input between 100 to 240 VAC 50/60Hz . WebInstall Greyline Logger on your PC or laptop. Refer to the Help menu in the program for detailed instructions. - Connect the PDFM 5.0 to the PC using the supplied USB cable. - Install the USB driver program from the install CD. - Start the Greyline Logger Software. gummy wheels roller skates https://needle-leafwedge.com

DFM 5.1 Doppler Flow Meter - Alpha Controls & Instrumentation …

WebUse the RS232 output and Greyline Logger software, the full report can be downloaded to your computer. PASSWORD ... Once the flow meter is calibrated you can come back to the DATA LOGGING menu and program as follows: ... 8 % Flow Flow Manual Series A.8. and . s to: FLOW mode.. n n n: Manual Series A.8. Important:. and , to C, ... WebThe level data is used with 'Greyline Logger' software to generate a flow report for the Parshall flume. The Stingray sensor was installed in the flume using the stainless steel mounting bracket supplied with each meter. A single screw is used to hold the ultrasonic level-velocity sensor in place at the correct position in the approach section ... http://www.fieldenvironmental.com/assets/files/Manuals/Greyline-PDFM-5-manual.pdf bowling monks cross york

PDFM 5.0 Portable Doppler Flow Meter - Water Online

Category:User

Tags:Greyline flow meter manual

Greyline flow meter manual

User

WebGreyline Instruments by Pulsar DFM 6.1 Doppler Flow Meter Accurate non-contacting flow measurement of "difficult" fluids from outside a pipe Starting At $3,922.00 CAD Normally ships in 1-2 Weeks Configure Request Quote Can We Help You? CALL US EMAIL US CHAT LIVE Our product experts are here to help you find the right solution for your … WebEnvironmental Equipment Air Quality Water Monitoring

Greyline flow meter manual

Did you know?

WebSummary of Contents for Greyline Instruments TTFM 1.0 Page 1 USER'S GUIDE Installation & Operation Instructions Transit Time Flow Meter Model TTFM 1.0 Manual Series A.3.4... Page 2 Note: This page has been left … WebUse this menu to set the corresponding flow rate that will be represented by 20mA analog output. If maximum flow is unknown, enter an estimated flow rate and observe actual …

WebUse the sensor coupling compound (supplied with each Greyline flow meter, or petroleum gel, acoustic compound or electrocardiograph gel). Take several readings around the … WebThe PDFM 5.0 includes a non-intrusive Doppler ultrasonic sensor for pipes from 1/2" to 180" (12.5 mm to 4.5 m) diameter, a stainless steel sensor mounting bracket and clamps, coupling compound and AC charger with a rugged IP67 carry case. It operates up to 18 hours from internal batteries and recharges overnight. Click Here To Download:

WebGreyline Instruments DFM-6.1 Manual Download for 1 www.greyline.com USER'S GUIDE Installation & Operation Instructions Doppler Flow Meter Model DFM 6.1 Manual Series A.1 Note: This page has been left blank intentionally. DFM 6.1 Doppler Flow Meter IMPORTANT NOTE: This instrument is manufactured and calibrated to meet product … WebThe DFM 6.1 Doppler Flow Meter includes an ultrasonic sensor, an easy to use 5-key configuration system, a large digital flow rate display with totalizer, isolated 4-20mA output, 26 million point data logger, and two programmable control relays.

WebGreyline PDFM 4.0 Displays, Datalogs Transmits and Totalizes Flow in Closed Pipes Fast, Easy Flow Measurement with Non-Contacting Ultrasonic Sensor For dirty or aerated liquids Simple 3-key Calibration 50,000 point Data Logger 4-20mA Output 10-Digit Totalizer AC/DC Operation Built-in Rechargeable Battery Non-Contacting Sensor

WebView and Download Greyline Instruments PT400 instruction manual online. Welcome to ManualMachine. ... Install sensors without cutting pipe so you can use the Portaflow as a spare or emergency transmitter when in-line flow meters fail. The analog output can be configured for 4-20mA or 0-20mA signal output. gummy weight loss shark tankWebUse this menu to set the corresponding flow rate that will be represented by 20mA analog output. If maximum flow is unknown, enter an estimated flow rate and observe actual flow to determine the correct maximum value. Any velocity or flow rate up to +40 ft/sec (12.2 m/sec) may be selected. gummy white dischargeWebCalibration is easy with the built-in 3 button keypad. The SLT32 offers simple menu selection of measurement units (gallons, liters etc.), calculates volume in horizontal round tanks, or flow rate (and total) through any flume or weir. Greyline Instruments Inc., 407 County Route 46, Massena, NY 13662-9510. Tel: 315-788-9500; Fax: 315-764-0419. bowling monmouth county njhttp://www.enviromark.ca/english/prodInfo/Greyline/OCF/OCF-IV%20Manual%20Series%20A8.pdf gummy weight loss oprahWebGreyline Doppler Flow Meters monitor the flow rate of 'difficult' liquids including: wastewater, chemicals, acids, slurries, abrasives and viscous liquids. Recommended for full pipes and any fluid that contains solids or bubbles. The DFM-IV strap-on sensor is mounted on the outside of a plastic or metal pipe. gummy white labelWebGreyline Logger Greyline Instruments Inc. www.greyline.com Menu Commands File Open, Close, Close All Save, Save As, Save All Export Graph..., Export Data... Print Recent Files List Exit Edit Copy Data View Change Units..., Customize Graph..., Data Table Graph Smoothing, Toolbar Data Logging Retrieve Log..., Real Time Monitor On/Off gummy will joseph cookWebMantaRay Portable Area-Velocity Flow Meter KEYPAD SYSTEM The MantaRay uses a menu system. Arrows show the four directions to leave a menu box. Pressing a … bowling monkey sacramento